Durex Industries manufactures nozzle thermocouples with various options.


Thermocouple Types

Thermocouple Type Codes Limits of Error
E J K T Standard Limits
2 3 4 8 Special Limits
 

Junction Type

Code Single Junction
G Grounded
U Ungrounded
 

Dimensional Chart

"L" Dimensions "B" Dimensions "A" Dimensions Fractional Dimension
Letter Codes
“L” dimensions are specified in whole inches and a single alpha character which represents a fraction. Enter the three digit code as follows: “B” dimensions are specified in fractions from ⅛” to 1”. Use the single alpha character to indicate the tip length. Enter the code as follows: “A” dimensions are
specified in whole inches only. Enter the three digit code as follows:
1/16" A 11/16" L
1/8" B 3/4" M
3/16" C 13/16" N
1/4" D 7/8" P
5/16" E 15/16" R
3" 030 10 5/8" 10K 3/8" F 1" S
4 1/2" 04H 12" 120 1/8" B 5/8" K 9" 009 7/16" G 0 No
6 1/4" 06D 15 3/8" 15F 1/4" D 3/4" M 12" 012 1/2" H    
7 7/8" 07P 17 3/4" 17M 3/8" F 7/8" P 36" 036 9/16" J    
9 5/8" 09K 22 1/8" 22B 1/2" H 1" S 144" 144 5/8" K    
 

Lead Wire Types

Leadwire Type Code Leadwire Type Descriptions
H Stranded Fiberglass Leadwirewith SS Overbraid
J Stranded Fiberglass Leadwirewith SS Armor
Standard assemblies supplied with stranded leadwire conductor. Solid conductor available upon request.
 

Termination Types

Termination Code Termination Description Thermocouple Style
0 2" Split Leads TNT1, TNT2, TNT3
1 #6 Spade Lugs TNT1, TNT2, TNT3
3 Standard Plug TNT1, TNT2, TNT3
4 Standard Jack TNT1, TNT2
 

Bolt Options

Bolt Type Bolt Descriptions
S 1/4 - 28
Y M 6 X 1
Z M 8 x 1.25
  
 

To learn more about our nozzle thermocouple solutions call us at (800) 739-9060 or contact us below.


Required Fields *
Contact Information
Name *
Email *
Company Name
Telephone Number
Product(s) interested in
Comments / Requests
Upload a document
{FILE_NAME}
Add a File